Architecture

Data flow

flowchart TD
    A["Kaggle LGG MRI Segmentation<br/>(Buda et al., TCGA)"]:::external
    A -->|sync_data.sh| B["data/raw/<br/>110 TCGA patient subdirs<br/>(paired .tif + _mask.tif)"]:::data
    B -->|prepare.py<br/>patient-level 88/11/11| C["data/processed/<br/>{train,val,test}/{images,masks}"]:::data
    C -->|SegmentationDataModule| D["Paired TIF loader<br/>(Lightning + Hydra)"]:::code
    D --> E["SegFormer-B2 (main)<br/>or U-Net-small (baseline)"]:::model
    E -->|MLflow tracking<br/>Dice + IoU + Pixel acc| F["artifacts/checkpoints/best.ckpt"]:::artifact
    F -->|evaluate.py| R["reports/metrics.json"]:::artifact
    F -->|publish_to_hf.py| G["HuggingFace Hub<br/>kiselyovd/brain-mri-segmentation"]:::external
    F -->|FastAPI| H["POST /segment<br/>PNG mask response"]:::serve

    classDef external fill:#EDE7F6,stroke:#673AB7,color:#311B92
    classDef data fill:#D1C4E9,stroke:#512DA8,color:#311B92
    classDef code fill:#B39DDB,stroke:#4527A0,color:#311B92
    classDef model fill:#9575CD,stroke:#311B92,color:#fff
    classDef artifact fill:#7E57C2,stroke:#311B92,color:#fff
    classDef serve fill:#673AB7,stroke:#311B92,color:#fff

Model choices

  • Main — SegFormer-B2. Hierarchical transformer encoder (nvidia/segformer-b2-finetuned-ade-512-512, ~25 M params) with a lightweight MLP decoder. Global self-attention captures long-range texture dependencies critical in MRI — tumor regions often lack sharp boundaries and require context beyond local receptive fields. Fine-tuned with the binary segmentation head replaced.
  • Baseline — U-Net (hand-rolled). Classic encoder-decoder with skip connections; 4 levels, 32→256 channels, ~1.9 M params. The dominant architecture in medical image segmentation literature. Serves as a meaningful upper bound for CNN-only methods; the main model must beat it to justify the transformer overhead.

Metrics

Metric Why
Dice coefficient Primary metric — measures overlap quality; penalises both false positives and false negatives equally
IoU (Jaccard) Strict overlap; harder to game than Dice; standard in segmentation benchmarks
Pixel accuracy Sanity check — trivially high when background dominates, so not used for model selection

Dice is used for early stopping and checkpoint selection. Pixel accuracy is logged but not reported as headline performance because the class imbalance (tumor pixels are a small fraction of each slice) makes it an unreliable indicator.

Key conventions

  • Patient-level split prevents data leakage — all slices from one patient stay in the same partition.
  • Images resized to 256 × 256 before the model; masks binarised at 0.5 threshold.
  • Checkpoint stores model_name in hyperparameters so inference.load_model can rebuild the backbone without caller-supplied metadata.
  • Lightning trainer seed-controlled via Hydra seed; deterministic mode on.